Product Range
 
Home >> Products
 

 THERMOCOUPLE EXTENSION AND COMPENSATING CABLES

Thermocouple extension cables / compensating cables are suitable for connection with thermocouples used for measurement and control of temperature. On the basis of environmental conditions, range of operation, period of operation and standard to be followed, a particular type of thermocouple and corresponding thermocouple extension cable are selected.

These cables are made from solid alloy wire or stranded conductors. The area of conductor varies from application to application.  The primary insulation over the conductors is provided by PVC compounds of different grades. The cores are coloured as per applicable standards and are twisted with an appropriate lay and staggered in a circular configuration for multi- pair cables. Pair identification is pro9vided by numbering. Shielding is provided by using conventional braid of copper / tinned copper or by using Al-Mylar tape in continuous contact with tinned copper drain wire (ECC).  The thermocouple extension cables are designed for smooth signal transmission and to reduce the effect of noise due magnetic interference and cross talk.

 
Code Conductor Combinations Approx. Generated Emf Change Per 0C Change With Reference Juncion AT 0 0 C. V/ 0 C At Approx. Working temprature range of measuring hunction National colour coding for thermocouple and extension cable
+LEG -LEG 1000C 5000C 10000C Continuous Short Term British  BS1843 American ANSI/MC 96.01 German DIN 43714 French NF C     42-323 Japanese JIS C             1610
KX Nickel-Chromium   (Chromel) Nickel- Aluminium   (Amulel) 42 43 39 0 to              +1100 -180 to              +1350 + :Orange   - :Blue          S:Red + :Yellow   - :Red      S:Yellow + :Red       - :Green          S:Green + :Yellow   - :Red      S:Yellow + :Red         - :White      S:Blue
VX Copper Copper- Nickel     (constantan) Used for interconnecting Type K Thermocouples only used where the interconnection temprature is between 00C to 80C + :White        - :Blue        S:Red     + :Yellow   - :Orange      S:Red + :Red         - :White      S:Blue
TX Copper Copper- Nickel     (constantan) 46     -185 to       +300 -250 to       +400 + :White        - :Blue        S:Blue + :Blue       - :Red     S:Blue + :Red       - :Orange          S:Orange + :Yellow   - :Blue    S:Blue + :Red         - :White      S:Orange
JX Iron Copper- Nickel     (constantan) 46 56 59 +20 to           +700 -180 to              +750 + :Yellow      - :Blue          S:Black + :White       - :Red     S:Black + :Red       - :Blue          S:Blue + :Yellow   - :Blue      S:Black + :Red         - :White      S:Yellow
EX Nickel-Chromium   (Chromel) Copper- Nickel     (constantan) 68 81   0 to                +800   + :Orange   - :Blue          S:Orange + :Pink         - :Red          S:Pink + :Red       - :Black          S:Black   + :Red         - :White      S:Pink
RX Platinum   13%        Rhodium Platinum 8 10 13 0 to              +1600 -50 to              +1700 + :White        - :Blue        S:Green + :Black               - :Red          S:Green     + :Red         - :White      S:Black
SX Platinum   10%        Rhodium Platinum 8 9 11 0 to              +1550 -50 to              +1700 + :White        - :Blue        S:Green + :Black               - :Red          S:Green + :Red       - :White          S:White + :Yellow   - :Green S:Green + :Red         - :White      S:Black
BX Platinum   30%        Rhodium Platinum 6%   Rhodium 1 5 9 +100 to              +1600 -50 to              +1750   + :Grey               - :Red          S:Grey + :Red       - :Grey          S:Grey   + :Red         - :White      S:Grey
UX Copper Copper Low  Value Nickel Used for interconnecting Type R and S Thermocouples only used where the interconnection temprature is between 00C to 500C + :White        - :Blue        S:Green + :Black               - :Red          S:Green + :Red       - :White          S:White + :Yellow   - :Green S:Green + :Red         - :White      S:Black
 

The data and information given herein are purely as a guide. VIRAL takes no responsibility for any damages arising out of incorrect use

 
Factory & Regd. Office : D-7, MIDC Ambad, Nashik - 422 010 , Mah. , India. Telephone : +91 253 2382340 / 2382430.FAX : +91 253 2382430.